Dajving Sistem

Sandwich panel buyer’s guide

How to plan buying roof, facade and cold-storage panels: from the building’s purpose and choosing the core and thickness to measurements, delivery, installation and maintenance. Step by step, with the most common mistakes to avoid.

Step 1

Define the building’s purpose

The building’s purpose decides everything else: the panel type, the core and the thickness. Before you ask for a quote, be clear about what the building is for and what conditions it has inside.

  • Heated buildings (production, offices) – good thermal insulation matters, so thicker panels.
  • Unheated buildings (warehouses, storage buildings, farm buildings) – thinner panels are often enough.
  • Cold stores and cold rooms – dedicated panels with greater thickness and airtightness are needed.
  • The project’s fire requirements – they decide between a PUR and a PIR core.
Step 2

Choose the panel type

Roof and facade panels are not interchangeable – they differ in sheet profile and in how they join.

  • Roof panels (Emante E-Roof) – a trapezoidal sheet with five ribs, for strength and water run-off; 30–120 mm thick.
  • Facade panels (Emante E-Wall) – a flat or profiled outer face, and a hidden-screw version; 30–120 mm thick.
  • Cold-storage panels (Emante E-Frigo) – a high-density core, 80–200 mm thick, with a hygienic surface.
Step 3

PUR or PIR core

Both are rigid polyurethane foams with excellent insulation at a low weight. The difference is fire behaviour: PIR (polyisocyanurate) performs better in a fire than PUR.

  • If the project sets no special fire requirements, PUR is the usual, economical choice.
  • For buildings with stricter fire requirements, choose PIR.
  • The reaction-to-fire class is set by the project – send us the project requirement and we will suggest a suitable panel.
Step 4

Thickness and insulation

The thicker the panel, the better it insulates. For Emante roof and facade panels the thermal transmittance (U) ranges from 0.71 W/m²K for the thinnest to 0.16 W/m²K for the thickest panels – a lower number means better insulation.

For heated buildings the required value is set by the designer, in line with energy-efficiency regulations. For cold stores the thickness depends on the operating temperature: the colder the space, the thicker the panel.

Tip: A thicker panel costs more to buy, but in heated and refrigerated buildings the difference is usually repaid through lower energy costs.

Step 5

Span and load capacity

Sandwich panels are self-supporting: they rest on purlins (roof) or facade rails (walls). The allowed distance between supports depends on the panel thickness and the loads – snow and wind at the building’s location.

  • Support spacing and loads are set by the structural designer.
  • If the structure is still being designed, match the support spacing to the chosen panel thickness – it is often cheaper than a thicker panel.
  • On request we send load tables for the chosen panel.
Step 6

Measurements, quantities and accessories

Emante panels are 1000 mm wide, and lengths are made to measure, from 2.5 to 17 m. Longer panels mean fewer cross joints, but more demanding transport and installation.

  • Measure the roof and walls, and allow for overhangs and openings for doors, gates and windows.
  • Order the accessories with the panels: sheet-metal flashings (ridge, edges, corners, around openings), self-drilling screws with sealing washers, and sealing tapes.
  • The most reliable way is to send us the project or a sketch with measurements – we will put together the panel and accessory specification.
Step 7

Colour and appearance

Roof panels come in six RAL colours and facade panels in twelve, plus 3D wood and 3D stone finishes. Panels in different colours can be combined in bands or fields.

  • Dark colours heat up more in the sun, which increases thermal expansion in long panels. In strong sun and with longer panels, consider lighter shades.
  • Facades with hidden screws or a microline profile look more even, with no visible screw heads.
Step 8

Delivery, unloading and storage

  • Make sure a truck with a long load can reach the site, and plan where to unload.
  • Unload packs with a forklift or a crane with straps of suitable length – never by dragging panels over the edge of the pack.
  • Store packs on flat, dry ground, on bearers, with a slight slope so water runs off, and cover them if they will stand for a while.
  • Do not walk on the packs or put loads on them.
  • Remove the protective film right after installation, or within the time the manufacturer recommends – film left in the sun becomes hard to remove.
Step 9

Installation

  • Have the panels installed by an experienced crew – we can do it too, together with the steel structure.
  • Use screws with sealing washers and do not over-tighten them – the washer should seal, not deform.
  • Cut panels with a saw or nibbler, not an angle grinder: the sparks damage the sheet’s protective coating and cause corrosion later.
  • Clean drilling and cutting swarf off the sheet the same day, so it leaves no rust marks.
  • Seal joints and flashings as the manufacturer instructs, especially in cold stores.
Step 10

Maintenance

  • Once a year, inspect the roof and facade: flashings, sealing tapes, screws and gutters.
  • Wash panels with water and a mild detergent, without abrasives.
  • Protect scratches in the sheet with suitable touch-up paint, so they do not corrode.
  • In cold stores, regularly check that joints and doors are airtight.

Panel types

The Emante panels we supply – the right choice depends on the building’s purpose, project and location.

Common mistakes

  • Choosing the thickness by price rather than by the building’s insulation needs.
  • Ignoring the project’s fire requirements when choosing the core.
  • Support spacing that does not match the panel thickness and the snow and wind loads.
  • Ordering panels without flashings, screws and seals – so installation stops until the accessories arrive.
  • Cutting panels with an angle grinder and leaving swarf on the sheet.
  • Storing packs directly on the ground, or leaving the protective film on too long.
  • Very long panels without checking truck access and how they will be unloaded.

What to prepare for your enquiry

With this information we can suggest suitable panels and prepare a quote.

  • The building’s purpose, and whether it is heated, unheated or refrigerated
  • Location of the building (town or municipality)
  • Building dimensions, roof and wall area
  • Roof pitch and support spacing, if known
  • The project’s insulation and fire requirements
  • Preferred colour and profile
  • Whether you also need installation or a steel structure
Send an enquiry

Frequently asked questions

What is the difference between PUR and PIR panels?

Both cores are rigid polyurethane foams with similar insulation. PIR performs better in a fire, so it is chosen when the project sets stricter fire requirements.

Which panel thicknesses are available?

Emante roof and facade panels are made 30 to 120 mm thick, and cold-storage panels 80 to 200 mm.

How long can the panels be?

Panels are made to measure, in lengths from 2.5 to 17 m, at a width of 1000 mm.

Which standard are the panels made to?

Emante panels are made to the European standard EN 14509, and the manufacturer holds ISO 9001 and EN 1090-1 certificates.

Do you also install panels and build steel structures?

Yes. Besides supplying panels, we build steel structures for halls, provide their fire protection and install the panels.

This guide is meant for planning. The right panel, thickness and support spacing for a specific building are set by its project – send an enquiry and we will help you choose.